Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Sci Rep ; 12(1): 3351, 2022 03 01.
Article in English | MEDLINE | ID: covidwho-1908222

ABSTRACT

Severe acute respiratory coronavirus 2 (SARS-CoV-2) has spread globally since its emergence in 2019. Most SARS-CoV-2 infections generate immune responses leading to rising levels of immunoglobulins (Ig) M, A and G which can be detected using diagnostic tests including enzyme-linked immunosorbent assays (ELISA). Whilst implying previous SARS-CoV-2 infection, the detection of Ig by ELISA does not guarantee the presence of neutralising antibodies (NAb) that can prevent the virus infecting cells. Plaque reduction neutralisation tests (PRNT) detect NAb, but are not amenable to mass testing as they take several days and require use of SARS-CoV-2 in high biocontainment laboratories. We evaluated the ability of IgG and IgM ELISAs targeting SARS-CoV-2 spike subunit 1 receptor binding domain (S1-RBD), and spike subunit 2 (S2) and nucleocapsid protein (NP), at predicting the presence and magnitude of NAb determined by PRNT. IgG S2 + NP ELISA was 96.8% [95% CI 83.8-99.9] sensitive and 88.9% [95% CI 51.8-99.7] specific at predicting the presence of NAbs (PRNT80 > 1:40). IgG and IgM S1-RBD ELISAs correlated with PRNT titre, with higher ELISA results increasing the likelihood of a robust neutralising response. The IgM S1-RBD assay can be used as a rapid, high throughput test to approximate the magnitude of NAb titre.


Subject(s)
Antibodies, Viral/immunology , COVID-19/immunology , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Neutralization Tests , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Aged , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged
2.
J Virol Methods ; 300: 114372, 2022 02.
Article in English | MEDLINE | ID: covidwho-1654861

ABSTRACT

The current gold standard technique for SARS-CoV-2 diagnostics is hydrolysis probe-based RT-qPCR. Reliable testing requires reliable control reagents to monitor the efficiency of RNA extraction, reverse transcription and PCR amplification. Here we describe a custom RNA packaging system from the plant virus cowpea mosaic virus to produce virus-like particles that encapsidate specifically designed portions of the genome of SARS-CoV-2, the causative agent of COVID-19. These encapsidated mimics are highly stable particles which can be used either to spike patient swab samples for use as an in-tube extraction and reaction positive control in multiplex RT-qPCR, or alone as a side-by-side mock-positive control reagent. The selection of sequences in the packaged pseudogenomes ensures that these mimics are compatible with the most commonly used primer/probe combinations for SARS-CoV-2 diagnostics (including German Berlin Charité Hospital, American CDC, and Chinese CDC protocols). The plant transient expression system used to produce these encapsidated mimics is inherently low-cost, and sufficiently high-yielding that a single laboratory-scale preparation can provide enough positive control reagent for millions of tests.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Indicators and Reagents , RNA, Viral/genetics , Sensitivity and Specificity
3.
J Infect ; 84(3): 355-360, 2022 03.
Article in English | MEDLINE | ID: covidwho-1560123

ABSTRACT

BACKGROUND: There are an abundance of commercially available lateral flow assays (LFAs) that detect antibodies to SARS-CoV-2. Whilst these are usually evaluated by the manufacturer, externally performed diagnostic accuracy studies to assess performance are essential. Herein we present an evaluation of 12 LFAs. METHODS: Sera from 100 SARS-CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) positive participants were recruited through the FASTER study. A total of 105 pre-pandemic sera from participants with other infections were included as negative samples. RESULTS: At presentation sensitivity against RT-PCR ranged from 37.4 to 79% for IgM/IgG, 30.3-74% for IgG, and 21.2-67% for IgM. Sensitivity for IgM/IgG improved ≥ 21 days post symptom onset for 10/12 tests. Specificity ranged from 74.3 to 99.1% for IgM/IgG, 82.9-100% for IgG, and 75.2-98% for IgM. Compared to the EuroImmun IgG enzyme-linked immunosorbent assay (ELISA), sensitivity and specificity ranged from 44.6 to 95.4% and 85.4-100%, respectively. CONCLUSION: There are many LFAs available with varied sensitivity and specificity. Understanding the diagnostic accuracy of these tests will be vital as we come to rely more on the antibody status of a person moving forward, and as such manufacturer-independent evaluations are crucial.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoassay , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity
4.
Sci Rep ; 11(1): 7754, 2021 04 08.
Article in English | MEDLINE | ID: covidwho-1174700

ABSTRACT

Serological testing is emerging as a powerful tool to progress our understanding of COVID-19 exposure, transmission and immune response. Large-scale testing is limited by the need for in-person blood collection by staff trained in venepuncture, and the limited sensitivity of lateral flow tests. Capillary blood self-sampling and postage to laboratories for analysis could provide a reliable alternative. Two-hundred and nine matched venous and capillary blood samples were obtained from thirty nine participants and analysed using a COVID-19 IgG ELISA to detect antibodies against SARS-CoV-2. Thirty eight out of thirty nine participants were able to self-collect an adequate sample of capillary blood (≥ 50 µl). Using plasma from venous blood collected in lithium heparin as the reference standard, matched capillary blood samples, collected in lithium heparin-treated tubes and on filter paper as dried blood spots, achieved a Cohen's kappa coefficient of > 0.88 (near-perfect agreement, 95% CI 0.738-1.000). Storage of capillary blood at room temperature for up to 7 days post sampling did not affect concordance. Our results indicate that capillary blood self-sampling is a reliable and feasible alternative to venepuncture for serological assessment in COVID-19.


Subject(s)
Blood Specimen Collection/methods , COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Adult , COVID-19/blood , Dried Blood Spot Testing/methods , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Male , Middle Aged , Young Adult
5.
Emerg Infect Dis ; 27(1)2021 01.
Article in English | MEDLINE | ID: covidwho-951873

ABSTRACT

We investigated the dynamics of seroconversion in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. During March 29-May 22, 2020, we collected serum samples and associated clinical data from 177 persons in London, UK, who had SARS-CoV-2 infection. We measured IgG against SARS-CoV-2 and compared antibody levels with patient outcomes, demographic information, and laboratory characteristics. We found that 2.0%-8.5% of persons did not seroconvert 3-6 weeks after infection. Persons who seroconverted were older, were more likely to have concurrent conditions, and had higher levels of inflammatory markers. Non-White persons had higher antibody concentrations than those who identified as White; these concentrations did not decline during follow-up. Serologic assay results correlated with disease outcome, race, and other risk factors for severe SARS-CoV-2 infection. Serologic assays can be used in surveillance to clarify the duration and protective nature of humoral responses to SARS-CoV-2 infection.


Subject(s)
COVID-19/blood , COVID-19/immunology , Immunoglobulin G/blood , SARS-CoV-2 , Seroconversion , Adult , Aged , Antibodies, Viral/blood , COVID-19/physiopathology , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged , Reverse Transcriptase Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL